TOP
CM Test system

Laser Module(TOF)

TERA-TOFAF

TOF auto focusing system

FEATURES

  • TOF auto focusing system
  • Semi auto(Auto handler optional), 1para
  • Test items : Gain calibration, auto focusing
  • Target device : TOF module

SPECIFICATION

Item Description
Test item Gain calibration, auto focusing
Target device TOF module
Socket/loading method 1 socket, Manual, Face Up(Auto handler optional)
Configuration for test SFR chart, Light source, 2 Visions(Top, bottom), Displacement sensor, Focusing Knob
Monitor 24” touch Monitor(2EA)
BCR 1 set
Air supply 5~7kg/㎤
Control PC I7 Quad Core, 16G Byte Memory, Window 10 64bit
Power AC220V, 50/60Hz 13A, 3 kW, 1 Phase
Weight 2,300kg
Dimension W2,200 x D2,000 x H2,300 (without Signal tower)